| Brand Name: | H3C |
| Model Number: | S10500X-G Series |
| MOQ: | 1 |
| Price: | Subject to the specific model and configuration |
| Payment Terms: | T/T |
| Supply Ability: | Up to 45 days |
H3C S10500X-G is a high-end Switch series designed for the core layer in intelligent Campuses and Data Centers. Powered by the H3C COMWARE 7 network operating system, the S10500X-G offers a comprehensive set of features tailored to both campus and data center environments, providing a secure and flexible platform for diverse types of network traffic. Architecturally, the S10500X-G adopts an industry-leading orthogonal CLOS+ forwarding architecture, ensuring long-term networking capabilities, making S10500X-G capable of building a high-performance network for years to come. In terms of services, with PoE++ capability, EERN (Enhanced Ethernet Ring Network) technology, and a variety of GE/10GE/25GE/40GE/100GE/400GE cards, along with wireless AC module, S10500X-G provides complete solutions for a wide range of scenarios. To ensure the network operating continuity, the S10500X-G delivers carrier-grade reliability, features redundant designs across key components including the Engine units (MPU), Switch Fabric units, fan trays, and power supply modules. Additionally, the S10500X-G embraces a Green and environmentally friendly design philosophy, with intelligent cooling system and reduced power consumption to promote energy efficiency.
S10500X-G incorporates the following advanced designs:
S10500X-G series adopts distributed system design for control engines, detection engines, and maintenance engines to deliver powerful control capability and millisecond-level HA.
S10500X-G Multigigabit Ethernet PoE++ Solution: With 48*10G Multigigabit PoE++ card, S10500X-G can provide an Easy-to-Deploy solution that can grow with customers’ business. It brings 5 times the current speed to the workspace in a way that plugs right into the existing cabling infrastructure, upgrades network capacity without disruption to business, delivers 15W, 30W, 60W and up to 90W (802.3bt standard) PoE out, powering more end-devices – IP phones, IPTVs, cameras, etc.
| Item | S10500X-G |
|---|---|
| VLAN | 4K |
| VLAN interface | 4K |
| MSTP instances | 64 |
| PVST/PVST+ instances | 126 |
| Jumbo frame length | 13312 |
| DHCP-security users | 16K |
| QOS forward queues | 8 |
| MAC address entries | 720,896 (Max) |
| IPv4 ARP entries | 96,230 (Max) |
| IPv6 ND entries | 81,350 (Max) |
| IPv4 routing entries | 780,288 (Max) |
| VRF | 4K (Max) |
| IPv4 ACL entries | Ingress: 26K (Max) Egress: 2K (Max) |
| IPv6 ACL entries | Ingress: 8K (Max) Egress: 1K (Max) |
| L2 Multicast entries | 8K (Max) |
| IPv6 routing entries | 278,528 (Max) |
| IPv4 Multicast entries | 8K (Max) |
| IPv6 Multicast entries | 8K (Max) |
| Buffer | 36MB (Max) |
| Features | S10506X-G S10506X-G-PoE |
S10508X-G | S10512X-G S10512X-G-PoE |
|---|---|---|---|
| Switching capacity | 43.2Tbps/76.8Tbps* | 57.6Tbps/153.6Tbps* | 86.4Tbps/230.4Tbps* |
| Forwarding capacity | 19200Mpps | 25600Mpps | 68400Mpps |
| MPU slots | 2 | ||
| MPU console ports | 1x RJ-45 | 1x RJ-45 | 1x RJ-45 |
| MPU MGMT ports | 1x 10/100/1000M RJ-45 1x 1000M SFP |
1x 10/100/1000M RJ-45 1x 1000M SFP |
1x 10/100/1000M RJ-45 1x 1000M SFP |
| MPU USB port | 1 | 1 | 1 |
| LPU slots | 6 | 8 | 12 |
| Switching fabric module slots | 4 | 6 | S10512X-G: 6 S10512X-G-PoE: 4 |
| Fan trays | 2 | 3 | S10512X-G: 3 S10512X-G-PoE: 2 |
| Power modules | 4 (non-PoE)+8 (PoE) | 6 | 8 (non-PoE)+16 (PoE) |
| Hardware architecture | Orthogonal CLOS+ | ||
| Redundancy | Redundant MPUs, switching fabric modules, power modules, and fan trays | ||
| Operating environment | Temperature: 0ºC to 45ºC (32°F to 113°F) Humidity: 5% to 95% (non-condensing) |
||
| Input voltage | AC:100V~240V DC:-48V~-60V |
||
| Maximum power consumption | 3012W | 4374W | 6309W |
| MTBF(Year) | 44.6 | 36.8 | 34.0 |
| MTTR(Hour) | 0.5 | 0.5 | 0.5 |
| Dimension (H x W x D)/mm | 442*440*520 10U |
531*440*640 12RU |
S10512X-G: 796*440*640; 18RU S10512X-G-PoE: 796*440*520; 18RU |
| Fully loaded weight | S10506X-G: < 85 kg/187.4 lb S10506X-G-PoE: < 95 kg/209lb |
< 130 kg < 286.6 lb |
S10512X-G: < 180 kg / < 396.8 lb S10512X-G-PoE: < 160 kg / < 352.73 lb |
| Feature | S10500X-G switch series |
|---|---|
| Ethernet |
IEEE 802.1Q VLAN DLDP LLDP Static MAC configuration MAC learning limit Port mirroring and traffic mirroring Mirroring, SPAN, RSPAN, ERSPAN with Max. 128 mirror groups Port aggregation,LACP, port isolation, and port mirroring 802.1d(STP)/802.1w(RSTP)/802.1s(MSTP)/PVST/PVST+ STP Root Guard BPDU Guard, BPDU filter IEEE 802.3ad (dynamic link aggregation), static port aggregation, and multi-chassis link aggregation IEEE 802.1P (CoS priority) IEEE 802.1ad (QinQ), selective QinQ and Vlan mapping GVRP RRPP (Rapid Ring Protection Protocol) Jumbo frame SuperVLAN PVLAN Guest VLAN Voice VLAN MVRP(IEEE802.1ak) Broadcast/multicast/unknown unicast storm constrain Port-based, Protocol-based, Subnet-based and MAC-based VLAN |
| Routing |
Static routing, RIPv1/v2, OSPF, IS-IS, and BGP4 ARP proxy ARP snooping DHCP client, DHCP server, DHCP relay, DHCP snooping, DHCP option82 DHCPv6 client, DHCPv6 server, DHCPv6 relay, DHCPv6 snooping, DHCPv6 option82 IPv4/IPv6 ECMP IPv4/IPv6 Policy-based routing IPv4/IPv6 Routing policy IPv4/IPv6 dual stack IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+ Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6 IPv4-to-IPv6 transition technologies, such as IPv6 manual tunnel, 6to4 tunnel, ISATAP tunnel, GRE tunnelIPv4-compatible IPv6 tunnel |
| Multicast |
PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, and Any-RP IGMP V1/V2/V3IGMP V1/V2/V3 Snooping IGMP Filter and IGMP Fast leave PIM snooping, IPv6 Pim-snooping Multicast VLAN PIM6-DMPIM6-SMPIM6-SSM MLD V1/V2, MLD V1/V2 Snooping Multicast policy and Multicast QoS |
| ACL/QoS |
Standard and extended ACLs Ingress and Egress ACL VLAN ACL Global ACL Ingress/Egress CAR Diff-Serv QoS 802.1P/DSCP Priority marking and remarking 802.1p, TOS, DSCP, and EXP priority mapping Flexible queue scheduling algorithms including SP, WRR, SP+WRR, WFQ Traffic shaping Congestion avoidance, Tail-Drop and WRED Ingress/Egress counting COPP |
| SDN/OpenFlow |
Support SDN solution (AD-Campus) OpenFlow 1.3 Multiple controllers (EQUAL, master/slave) Multiple tables flow Group table Meter |
| VXLAN |
VXLAN L2 switching VXLAN L3 routing VXLAN VTEP L2 VxLAN gateway, L3 VxLAN gateway Distributed VxLAN gateway, Centralized VxLAN gateway IPv4/IPv6 VxLAN tunnel VXLAN OAM ping/tracert IS-IS+ENDP distributed control plane MP-BGP+EVPN distributed control plane, EVPN-DCI* EVPN ESI* OpenFlow+Netconf centralized control plane |
| Programmability and automation |
Ansible Auto DevOps by using Python, NETCONF, TCL, and Restful APIs for automated network programming |
| Lossless Ethernet |
PFC* ECN* RoCEv2* |
| MPLS/VPLS |
L3 MPLS VPN L2 VPN: VLL (Martini, Kompella) MCE MPLS OAM VPLS, VLL P/PE function LDP |
| Multiservice convergence |
Integrated AC, Unified Wireless Access Controller, (LSEM1SUPA0, LSEM1SUPB0 support integrated AC) AP Auto Registration Wireless User WPA2 + PSK Authentication Wireless User Portal Authentication |
| Security |
Hierarchical user management and password protection EAD Port security Portal authentication MAC authentication IEEE 802.1x and IEEE 802.1x SERVER AAA/Radius TACACS+ HWTACACS (HW Terminal Access Controller Access Control System) (Same authentication processes and implementations with TACACS+) SSHv1.5/SSHv2 Basic and advanced ACLs for packet filtering OSPF, RIPv2, BGPv4 plain text and MD5 authentication IP address, VLAN ID, MAC address multiple binding combination MACsec uRPF HTTPS SSL PKI Secure boot TPM, Trust computing Active/standby data backup Micro-segmentation |
| System management |
IMC network management system Loading and upgrading through XModem/FTP/TFTP SNMP v1/v2c/v3 SmartMC sFlow, Netstream Telemetry INT* MOD (Mirror on drop) Packet capture gRPC Telemetry Stream* RMON and groups 1,2,3 and 9 NTP and PTP (1588v2) NQA, iNQA Fault alarm and automatic fault recovery System logs with a maximum of 20 remote loghosts / logservers ZTP Ping, Tracert, VxLAN ping and VxLAN tracert eMDI* Cloud management Device status monitoring mechanism, including the CPU engine, backplane, chips and other key components |
| HA |
Independent switching fabric modules 1+1 redundancy for key components such as MPUS and M+N redundancy for power modules N+1 redundancy for switching fabric modules Passive backplane Hot swapping for all components Real-time data backup on active/standby MPUs CPU protection IP source guard Loop detection Ethernet OAM VRRP, VRRPv3 Hot patching NSR/GR for OSPF/BGP/IS-IS Port aggregation and multi-card link aggregation, LACP BFD for VRRP, BGP/BGPv4, IS-IS/IS-ISv6, PIM/PIM for IPV6, OSPF/OSPFv3, static routing, with a failover detection time less than 50 milliseconds Hardware BFD Ethernet QAM (802.1ag and 802.3ah) RRPP/ERPS/EERN VCT Track Monitor Link Smart-Link IRF ISSU M-LAG S-MLAG MDC Loopback Detection |
| Green |
IEEE (802.3az) |
| EMC |
FCC Part 15 Subpart B CLASS A ICES-003 CLASS A VCCI CLASS A CISPR 32 CLASS A EN 55032 CLASS A AS/NZS CISPR32 CLASS A CISPR 24 EN 55024 EN 61000-3-2 EN 61000-3-3 ETSI EN 300 386 |
| Safety |
UL 60950-1 CAN/CSA C22.2 No 60950-1 IEC 60950-1 EN 60950-1 AS/NZS 60950-1 FDA 21 CFR Subchapter J GB 4943.1 |
Ordering Information
| Product code | Description | |
|---|---|---|
| Chassis | LS-10506X-G | H3C S10506X-G Ethernet Switch Chassis |
| LS-10506X-G-PoE | H3C S10506X-G Ethernet Switch Chassis, PoE | |
| LS-10508X-G | H3C S10508X-G Ethernet Switch Chassis | |
| LS-10512X-G | H3C S10512X-G Ethernet Switch Chassis | |
| LS-10512X-G-PoE | H3C S10512X-G Ethernet Switch Chassis, PoE | |
| Power supply module | PSR1600B-12A-B | 1600W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| PSR2000-12D-B | 2000W DC Power Supply Module(Power Panel Side Exhaust Airflow) | |
| PSR1600-54A-B | 1600W/56V PoE Power Supply Module (Power Panel Side Exhaust Airflow) | |
| Fan tray module | FAN-80B-4-A | Fan Tray Module |
| FAN-80B-5-A | Fan Tray Module | |
| FAN-80B-8-A | Fan Tray Module | |
| FAN-80B-8-B-G3 | Fan Tray Module | |
| Supervisor engine | LSEM1SUPA0 | H3C S10500X-G Supervisor Engine Unit,Type A |
| LSEM3SUPA0 | H3C S10500X-G Supervisor Engine Unit,Type A | |
| LSEM1SUPB0 | H3C S10512X-G Supervisor Engine Unit,Type B | |
| LSEM3SUPB0 | H3C S10512X-G Supervisor Engine Unit,Type B | |
| Switch fabric unit | LSEM1SF06B0 | H3C S10506X-G Switch Fabric Module,Type B |
| LSEM1SF06D0 | H3C S10506X-G Switch Fabric Module,Type D | |
| LSEM1SF08C0 | H3C S10508X-G Switch Fabric Module,Type C | |
| LSEM1SF12B0 | H3C S10512X-G Switch Fabric Module,Type B | |
| LSEM1SF12PB0 | H3C S10512X-G Switch Fabric Module, Type B | |
| Line card | LSEM1GT48TSSD0 | H3C S10500X-G 48-Port 10/100/1000BASE-T Interface(RJ45)+4-Port 10G Ethernet Optical Interface Module (SFP+,LC)(SD) |
| LSEM1GT48SD0-G3 | H3C S10500X-G 48-Port 10/100/1000BASE-T Ethernet Copper Interface Module (RJ45)(SD) | |
| LSEM1GP48SD0-G3 | H3C S10500X-G 48-Port 1000BASE Ethernet Optical Interface Module (SFP)(SD) | |
| LSEM1GV48TSSD0 | H3C S10500X-G 48-Port 10/100/1000BASE-T Interface(RJ45)+4-Port 10G Ethernet Optical Interface Module (SFP+)(SD),PoE Plus | |
| LSEM1GP40TS12SD0-G3 | H3C S10500X-G 40-Port 1000BASE Ethernet Optical Interface (SFP)+12-Port 10G Ethernet Optical Interface Module (SFP+)(SD) | |
| LSEM1GT24GP16TSSD0 | H3C S10500X-G 24-Port 10/100/1000BASE-T Ethernet Copper Interface(RJ45)+16-Port 1000BASE Ethernet Optical Interface(SFP)+12-Port 10G Ethernet Optical Interface Module (SFP+)(SD) | |
| LSEM2TGS16GP32SD0 | H3C S10500X-G 16-Port 10G Ethernet Optical Interface(SFP+) + 32-Port 1000BASE Ethernet Optical Interface Module (SFP)(SD) | |
| LSEM1TGS24SD0 | H3C S10500X-G 24-Port 10G Ethernet Optical Interface Module (SFP+,LD)(SD) | |
| LSEM1TGS48QSSF0 | H3C S10500X-G 48-Port 10G Ethernet Optical Interface(SFP+,LC)+4-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) | |
| LSEM3TGS48QSSF0 | H3C S10500X-G 48-Port 10G Ethernet Optical Interface(SFP+) + 4-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) | |
| LSEM1TGT48SD0 | H3C S10500X-G 48-Port Multigigabit Ethernet (10G/5G/2.5G/1G/100Mbps) Copper Interface Module (RJ45)(SD) | |
| LSEM1TGV48SD0 | H3C S10500X-G 48-Port Multigigabit (10G/5G/2.5G/1G/100Mbps) Ethernet Copper Interface Module (RJ45)(SD),Separate License Required for 10G/5G,PoE++ | |
| LSEM2TGS48SD0 | H3C S10500X-G 48-Port 10G Ethernet Optical Interface Module (SFP+)(SD) | |
| LSEM1YGS48CQSF0 | H3C S10500X-G 48-Port 25G Ethernet Optical Interface (SFP28)+4-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) | |
| LSEM3YGS48CQSF0 | H3C S10500X-G 48-Port 25G Ethernet Optical Interface (SFP28) + 4-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) | |
| LSEM1QGS16SF0 | H3C S10500X-G 16-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) | |
| LSEM3QGS16SF0 | H3C S10500X-G 16-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) | |
| LSEM1QGS36SF0 | H3C S10500X-G 36-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) | |
| LSEM3QGS36SF0 | H3C S10500X-G 36-Port 40G Ethernet Optical Interface Module (QSFP+)(SF) | |
| LSEM1GT48TS24QSSD0 | H3C S10500X-G 48-Port 10/100/1000BASE-T Ethernet Copper Interface(RJ45)+24-Port 10G Ethernet Optical Interface(SFP+)+2-Port 40G Ethernet Optical Interface Module (QSFP+)(SD) | |
| LSEM1CGQ16SF0 | H3C S10500X-G 16-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) | |
| LSEM3CGQ16SF0 | H3C S10500X-G 16-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) | |
| LSEM1CGQ36SF0 | H3C S10500X-G 36-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) | |
| LSEM3CGQ36SF0 | H3C S10500X-G 36-Port 100G Ethernet Optical Interface Module (QSFP28)(SF) | |
| LSEM3CDQ2SF0 | H3C S10500X-G 2-Port 400G Ethernet Optical Interface Module (QSFP-DD)(SF) | |
| LSEM1RCGQ2TSSF0 | H3C S10500X-G 2-Port 100G RPR Optical Interface(QSFP28)+16-Port 10G Ethernet Optical Interface Module (SFP+)(SF) | |
| LSEM1WBC120G0 | H3C S10500X-G Multiservice Access Controller Module(10240 AP,120G) | |
| LSEM1SDNB0 | H3C S10500X-G SDN Automation Module | |