| Nazwa marki: | H3C |
| Numer modelu: | Seria S5590-EI |
| MOQ: | 1 |
| Cena: | Subject to the specific model and configuration |
| Warunki płatności: | T/T |
| Możliwość zaopatrzenia: | do 45 dni |
H3C S5590-EI series switches are a new generation of high-performance, high-port density, high-security Layer 3 Ethernet switches developed by H3C Technology Co., Ltd. (hereinafter referred to as H3C) using industry-leading ASIC technology, supporting IPv4/IPV6 Dual-stack management and forwarding, support static routing protocols and routing protocols such as RIP, OSPF, BGP, ISIS, etc., and support rich management and security features. It is a Gigabit Layer 3 Ethernet switch product for converged service networks.
In the campus network, H3C S5590-EI series switches can be used as aggregation layer equipment, or as the core of small and medium-sized enterprises; downward can provide high-density GE and MultiGiga ports, upward through 10G/25G/40G/100G fiber or link aggregation is aggregated to the core switch to build a high-performance end-to-end IP network solution together with other H3C products.
H3C S5590-EI series switches include the following models:
H3C S5590-EI series switches support Telemetry technology, which can send the switch's real-time resource information and alarm information to the O&M platform through the gRPC protocol.
The platform can realize network quality backtracking, troubleshooting, risk early warning, architecture optimization and other functions to accurately guarantee user experience by analyzing real-time data.
H3C S5590-EI series switches support iNQA. iNQA provides the following benefits:
H3C S5590-EI series switches support M-LAG, which enables links of multiple switches to aggregate into one to implement device-level link backup. M-LAG is applicable to servers dual-homed to a pair of access devices for node redundancy.
MACsec (Media Access Control Security, MAC security) defines the method of data security communication based on IEEE 802 local area network. MACsec can provide users with secure MAC layer data transmission and reception services, including user data encryption, data frame integrity check and data source authenticity verification.
MACsec is usually used in conjunction with the 802.1X authentication framework. After the 802.1X authentication process is successful, it identifies the message sent by the authenticated device and uses the MKA (MACsec Key Agreement, MACsec Key Agreement) protocol to negotiate the generated key pair Authenticated user data is encrypted and integrity checked to prevent the port from processing packets from unauthenticated devices or tampered with unauthenticated devices.
H3C S 5590-EI series switches support upgraded MACsec encryption technology and use 256-bit encryption algorithm to further improve data security; All ports of the device provide 256-bit MACsec encryption to ensure data security.
H3C S5590-EI series switches support the 1588V2 function to meet the high-precision time synchronization requirements between network devices. Compared with GPS time synchronization with the same precision, it improves security and lowers deployment costs.
Based on H3C's Open Service Architecture (OAA), H3C S5590-EI series switches can not only provide the functions of traditional switches, but also integrate security module cards including FW, IPS, and load balancing, mini-iMC cards, and Eagle Vision cards. etc., making the S5590-EI series switches a converged multi-service bearing platform.
H3C S5590-EI series switches support the EAD ( terminal access control ) function, and cooperate with the background system to integrate terminal security measures such as terminal antivirus and patch repair with network security measures such as network access control and access authority control into a linked security The system, through the inspection, isolation, repair, management and monitoring of network access terminals, makes the entire network change from passive defense to active defense, from single-point defense to comprehensive defense, and from decentralized management to centralized policy management. , worms and other emerging security threats overall defense capabilities.
H3C S5590-EI series switches support centralized MAC address authentication, 802.1x authentication, support dynamic or static binding of user identification elements such as user account, IP, MAC, VLAN, and port, and implement user policies (VLAN, QoS, ACL) dynamic distribution; support with H3C's iMC system for real-time management of online users, timely diagnosis and disintegration of illegal network behavior.
H3C S5590-EI series switches provide enhanced ACL control logic, support large-capacity ingress and egress port ACLs, and support VLAN-based ACL delivery, which simplifies the user configuration process and avoids waste of ACL resources. In addition, H3C S5590-EI series switches will also support unicast reverse path finding technology (uRPF). The route between the interface and the source address specified in the packet is to verify its authenticity. If it does not exist, the packet is deleted, so that we can effectively prevent the source address spoofing that is increasingly flooding in the network.
| Feature | S5590-24UXM4YC-EI | S5590-48UXM4YC-EI | S5590-24UXMC-EI |
|---|---|---|---|
| Port Switching Capacity | 792Gbps | 984Gbps | 880Gbps |
| Packet Forwarding Capacity | 660Mpps | 660Mpps | 660Mpps |
| Switching Capacity | 2.4Tbps | 2.4Tbps | 2.4Tbps |
| Dimensions (W*D*H) (unit: mm ) | 440*400*44 | 440*400*44 | 440*400*43.6 |
| Weight | ≤6.8kg | ≤7kg | ≤7.5kg |
| Console port | 1 | ||
| Flash/SDRAM | 8G/2G | ||
| Packet Buffer | 4.5M | ||
| Ethernet port for management | 10/100/1000Base-T electrical port: 1 | ||
| USB port | 1 | ||
| 10/100/1000BASE-T port (PoE++) | 16 | 32 | - |
| 10M/100M/1G/2.5G/5G/10G Base-T Ports (PoE++) | 8 | 16 | 24 |
| 1G/10G/25GBase-X SFP28 | 4 | 4 | - |
| Expansion card slot | 1 | ||
| PoE | PoE++ support | ||
| Input voltage | AC: Rated voltage range: 100 to 240V AC: 50/60Hz | ||
| Power Supply slots | 2(Hot swappable) | ||
| Machine leakage current | Meet UL60950-1/EN60950-1/IEC60950-1 /GB4943 standard | ||
| Working temperature | -5 ºC to 45 ºC | ||
| Relative humidity of working environment (non-condensing) | 5 % to 95 % | ||
| Feature | S5590-EI Series Switches |
|---|---|
| Ethernet Configuration |
Cross-device link aggregation Static aggregation Dynamic aggregation AutoMDIX LRM (Long Reach Multimode) (LSWM4SP8PM can support LRM transceiver) Speed Auto/Manual Duplex Auto/Full/Half |
| Port Characteristics |
Support IEEE802.3x flow control (full duplex) Supports storm suppression based on port rate percentage Supports PPS-based storm suppression Support bps-based storm suppression |
| MAC address table |
Support black hole MAC address Supports setting the maximum number of port MAC addresses to learn |
| VLAN |
Access/Trunk/Hybrid VLAN Port-based VLAN support MAC-based VLAN IP subnet-based VLAN Protocol-based VLAN IEEE 802.1P(CoS priority) Super VLAN Private VLAN Voice VLAN Support QinQ, flexible QinQ Support VLAN Mapping Support Private VLAN Support Voice VLAN QinQ (802.1Q-in-802.1Q) VLAN mapping Static/Dynamic/Blackhole/Multiport unicast MAC MAC automatic learning and aging Port-based/VLAN-based MAC learning limit MAC filter Port isolation VLAN ID range 0 to 4095(Total 4096) IEEE 802.3x flow control (full duplex) Storm suppression based on port rate percentage PPS -based storm suppression bps -based storm suppression LLDP (Link Layer Discovery Protocol) and LLDP-MED (Link Layer Discovery Protocol Media Endpoint Discovery) Broadcast/multicast/unknown unicast storm constrain Jumbo frame Store-and-forward (Default) |
| Layer 2 Ring Network Protocol |
Loop detection (VLAN and VXLAN network) MVRP (Multiple VLAN Registration Protocol) GVRP (Generic VLAN Registration Protocol) PVST (Per-VLAN Spanning Tree) (compatible with PVST+/RPVST+) Support STP/RSTP/MSTP Support SmartLink Support RRPP Support ERPS (G.8032) Ethernet ring network protection switching BPDU/root/loop/TC-BPDU/PVST BPDU/disputeloopback guard BPDU filter Role/TC-BPDU transmission restriction Support port single-pass detection, Edge Port |
| IRF2 Intelligent Resilience Architecture |
Support IRF2 Intelligent Resilience Architecture (fast convergence within 50ms) Support distributed device management, distributed link aggregation, distributed elastic routing Supports stacking via standard Ethernet interfaces, etc. Supports local stacking and remote stacking |
| IP Services |
Static/Dynamic/Gratuitous/proxy ARP ARP snooping/fast-reply/direct route advertisement/ping ARP attack detection ARP source suppression Ping, Tracert DHCP (Dynamic Host Configuration Protocol) DHCP Server/relay agent/client/snooping DHCP Option 43, Option 82, and Option 184, DNS (Domain Name System) DDNS (Dynamic Domain Name System) mDNS (Multicast Domain Name System) IRDP (ICMP Router Discovery Protocol) UDP helper ND (Neighbor Discovery) ND snooping/proxy/direct route advertisement/ping DHCPv6 Server/relay agent/client/snooping/guard GRE (Generic Routing Encapsulation) HTTP redirect GRE tunneling VXLAN tunneling and VXLAN-DCI tunneling IPv4/IPv6 over IPv4 tunneling, and IPv4/IPv6 over IPv6 tunneling IPv4/IPv6 Fast Forwarding |
| IP routing |
Support static routing Support RIPv1/v2, RIPng Support OSPFv1/v2, OSPFv3 Support BGP4, BGP4+ for IPv6 Support IS-IS, IS-IS V6 Support equal-cost routing, policy routing Support VRRP/VRRPv3 Support O SPF multi-process, MD5 encryption authentication, S TUB/NSSA area Support route COST setting, support inter-area route filtering |
| IPv6 |
Support IPv4/IPv6 dual stack protocol Support ND (Neighbor Discovery) Support PMTU Support IPv6-Ping, IPv6-Tracert, IPv6-Telnet, IPv6-TFTP, IPv6 - ICMP, IPv6 -DNS, IPv6-FTP, IPv6-NTP Support manual tunnel, automatic tunnel IPv4 support over IPv6 tunnel Support 6to4 tunnel Support ISATAP tunnel Support GRE tunnel |
| Multicast |
PIM-DM, PIM-SM, PIM-SSM, and Any-RP PIM snooping IGMPv1/IGMPv2/IGMPv3 IGMP proxying IGMP Snooping IGMP snooping proxying IGMP Filter and IGMP Fast leave IPv6 PIM-DM, PIM-SM, PIM-SSM, and Any-RP IPv6 PIM snooping MLDv1/MLDV2 MLD proxying MLD Snooping MLD snooping proxying Multicast routing and forwarding Multicast VLAN MVPN (Multicast VPN) Multicast policy and Multicast QoS Support MSDP, MSDP for IPv6 Support MBGP, MBGP for Ipv6 |
| Mirror |
Stream mirroring supported Support N:4 port mirroring Supports local and remote port mirroring Support ERS PAN |
| ACLQoS |
Support L2 (Layer 2) ~ L4 (Layer 4) packet filtering function, provide based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, TCP/UDP port number, Traffic Classification for VLANs Support Time Range ACL Supports bidirectional ACL policies in inbound and outbound directions Supports issuing ACLs based on VLANs Supports limiting the rate at which the port receives packets and the rate at which it sends packets Support message redirection Diff-Serv QoS Eight queues each interface 802.1p, TOS, DSCP, and EXP priority mapping 802.1p and DSCP priority re-marking of packets Support CAR (Committed Access Rate) function Support flexible queue scheduling algorithm, can be set based on port and queue at the same time, support SP, WFQ, SP+WFQ three modes Traffic shaping Time ranges Traffic classification based on source MAC, destination MAC, source IP, destination IP, port, protocol, and VLAN Congestion avoidance, Tail-Drop, RED (Random Early Detection) and WRED (Weighted Random Early Detection) |
| MPLS |
Static LSP (label switched path) LDP (Label Distribution Protocol) IPv6 LDP Tunnel policies VRF (Virtual Routing and Forwarding) Support MPLS MCE MPLS support L3VPN MPLS support L2VPN MPLS support SR MPLS Ping/Tracert MCE (Multi-VPN Instance Customer Edge) IPv6 MCE MPLS OAM |
| VxLAN |
Support VxLAN Layer 2 and Layer 3 gateways Support VxLAN routing Centralized VXLAN gateway Distributed VXLAN gateway VXLAN M-LAG VXLAN-DCI OVSDB (Open vSwitch Database) VXLAN VTEP MP-BGP EVPN control plane EVPN VXLAN EVPN M-LAG |
| Safety features |
Support RBAC (Role-based access control) Support user hierarchical management and password protection Support 802.1X authentication / centralized MAC address authentication Support Portal authentication Support Guest VLAN Support AAA (Authentication, Authorization, and Accounting) Support RADIUS authentication Support HW TACACS+ certification Support MAC authentication Support Web authentication Support Triple authentication Support Guest VLAN SSH1.x and SSH2.0(Secure Shell) SSL (Secure Sockets Layer) HTTPs Support port isolation Support port security Support EAD Support SAVI and SAVA to ensure the security of IPv6 environment Support DHCP Snooping to prevent spoofed DHCP server Support dynamic ARP inspection to prevent man-in-the-middle attacks and ARP denial of service Support BPDU guard, Root guard Support uRPF (Unicast Reverse Path Detection) to prevent IP source address spoofing and prevent viruses and attacks Support IP/Port/MAC binding function Control Plane Protection (CoPP), Wireless Intrusion Prevention System (WIPS) Attack detection and prevention TCP attack prevention IPSG (IP source guard) IPv6 RA Guard ARP attack protection ND attack protection MFF (MAC-forced forwarding) SAVI (Source Address Validation Improvement) FIPS (Federal Information Processing Standards) MACsec (Media Access Control Security) All ports AES256 MACsec Microsegmentation Hierarchical user management and password protection Basic and advanced ACLs for packet filtering Support OSPF, RIPv2 message plaintext and MD5 ciphertext authentication Support PKI (Public Key Infrastructure, public key infrastructure) |
| Network Management |
NQA (Network quality analyzer) iNQA (Intelligent Network Quality Analyzer) eMDI (Enhanced Media Delivery Index) Performance management through gRPC or NETCONF NTP (Network Time Protocol) Support hot patch function, online patch upgrade Support XModem /FTP/TFTP loading and upgrading Support command line interface (CLI), Telnet, Console port for configuration Support netcool network management platform Support SNMPv1/v2/v3, RMON (Remote Monitoring) BFD support for VRRP/IS-IS/BGP/RIP/OSPF/Static Routing Support iMC intelligent management center Support Syslog, system log, hierarchical alarm, debug information output NTP support Support power alarm function, fan, temperature alarm Support Ping, Tracert Support VCT (Virtual Cable Test) cable detection function Support DLDP (Device Link Detection Protocol) unidirectional link detection protocol Port mirroring SPAN (Switch Port Analyzer)/RSPAN (Remote SPAN) Flow mirroring N:4 port mirroring local and remote port mirroring sFlow Information center NETCONF/YANG (XML-based network management protocol) Support Python script management operation and maintenance Support Loopback-detection port loopback detection Support NetStream function, traffic analysis sampling ratio 1:1 Supportbuilt-inWebGUI Support secure boot |
| OpenFlow |
OpenFlow 1.3 Multiple controllers (EQUAL, master/slave) Multiple tables flow Group table |
| Energy Saving |
Port automatic power down function Port timing down function (Schedule job) Support EEE (802.3az) energy saving standard |
| Entries | S5590-EI Series Switches |
|---|---|
| MAC address entries | max 320K |
| VLAN table | 4K |
| VLAN interface | 4093 |
| IPv4 routing entries | max 80K |
| IPv4 ARP entries | 65015 |
| IPv4 ACL entries |
IN: 3.25K EG: 0.75K |
| IPv4 multicast L2 entries | 8K |
| IPv4 multicast L3 entries | 4K |
| IPv6 unicast routing entries | 32K |
| QOS forward queues | 8 |
| IPv6 ACL entries |
Ingress: 1.625K Egress: 0.375 |
| IPv6 ND entries | 32K |
| IPv6 multicast L2 entries | 8K |
| IPv6 multicast L3 entries | 4K |
| Jumbo frame length | 13312 |
| MAX num in one link group | 64 |
| Link group num | 256 |
| Max Stacking Members | 9 |
| Max Stacking Bandwidth | 480Gbps |
| Power supply 1 | Power supply 2 | S5590-24UXM4YC-EI | S5590-48UXM4YC-EI | ||
|---|---|---|---|---|---|
| Total PoE power capacity | PoE Ports Quantity | Total PoE power capacity | PoE Ports Quantity | ||
| PSR600-54A-B | / | 450W | 15.4W (802.3af): 24 | 450W | 15.4W (802.3af): 29 |
| 30W (802.3at): 15 | 30W (802.3at): 15 | ||||
| 60W (802.3bt): 7 | 60W (802.3bt): 7 | ||||
| 90W (802.3bt): 5 | 90W (802.3bt): 5 | ||||
| PSR920-54A-B | / | 770W | 15.4W (802.3af): 24 | 770W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 25 | ||||
| 60W (802.3bt): 12 | 60W (802.3bt): 12 | ||||
| 90W (802.3bt): 8 | 90W (802.3bt): 8 | ||||
| PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | / | 770W | 15.4W (802.3af): 24 | 770W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 25 | ||||
| 60W (802.3bt): 12 | 60W (802.3bt): 12 | ||||
| 90W (802.3bt): 8 | 90W (802.3bt): 8 | ||||
| PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | / | 1450W | 15.4W (802.3af): 24 | 1450W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 48 | ||||
| 60W (802.3bt): 24 | 60W (802.3bt): 24 | ||||
| 90W (802.3bt): 16 | 90W (802.3bt): 16 | ||||
| PSR600-54A-B | PSR600-54A-B | 1020W | 15.4W (802.3af): 24 | 1020W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 34 | ||||
| 60W (802.3bt): 17 | 60W (802.3bt): 17 | ||||
| 90W (802.3bt): 11 | 90W (802.3bt): 11 | ||||
| PSR600-54A-B | PSR920-54A-B | 1020W | 15.4W (802.3af): 24 | 1020W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 34 | ||||
| 60W (802.3bt): 17 | 60W (802.3bt): 17 | ||||
| 90W (802.3bt): 11 | 90W (802.3bt): 11 | ||||
| PSR600-54A-B | PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | 1020W | 15.4W (802.3af): 24 | 1020W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 34 | ||||
| 60W (802.3bt): 17 | 60W (802.3bt): 17 | ||||
| 90W (802.3bt): 11 | 90W (802.3bt): 11 | ||||
| PSR600-54A-B | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 1020W | 15.4W (802.3af): 24 | 1020W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 34 | ||||
| 60W (802.3bt): 17 | 60W (802.3bt): 17 | ||||
| 90W (802.3bt): 11 | 90W (802.3bt): 11 | ||||
| PSR920-54A-B | PSR920-54A-B | 1600W | 15.4W (802.3af): 24 | 1600W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 48 | ||||
| 60W (802.3bt): 24 | 60W (802.3bt): 26 | ||||
| 90W (802.3bt): 17 | 90W (802.3bt): 17 | ||||
| PSR920-54A-B | PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | 1260W | 15.4W (802.3af): 24 | 1260W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 42 | ||||
| 60W (802.3bt): 21 | 60W (802.3bt): 21 | ||||
| 90W (802.3bt): 14 | 90W (802.3bt): 14 | ||||
| PSR920-54A-B | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 1600W | 15.4W (802.3af): 24 | 1600W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 48 | ||||
| 60W (802.3bt): 24 | 60W (802.3bt): 26 | ||||
| 90W (802.3bt): 17 | 90W (802.3bt): 17 | ||||
| PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | 1600W | 15.4W (802.3af): 24 | 1600W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 48 | ||||
| 60W (802.3bt): 24 | 60W (802.3bt): 26 | ||||
| 90W (802.3bt): 17 | 90W (802.3bt): 17 | ||||
| PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 1600W | 15.4W (802.3af): 24 | 1600W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 48 | ||||
| 60W (802.3bt): 24 | 60W (802.3bt): 26 | ||||
| 90W (802.3bt): 17 | 90W (802.3bt): 17 | ||||
| PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 2850W | 15.4W (802.3af): 24 | 2850W | 15.4W (802.3af): 48 |
| 30W (802.3at): 24 | 30W (802.3at): 48 | ||||
| 60W (802.3bt): 24 | 60W (802.3bt): 47 | ||||
| 90W (802.3bt): 24 | 90W (802.3bt): 31 | ||||
| Power supply 1 | Power supply 2 | S5590-24UXMC-EI | |
|---|---|---|---|
| Total PoE power capacity | PoE Ports Quantity | ||
| PSR600-54A-B | / | 450W | 15.4W (802.3af): 24 |
| 30W (802.3at): 15 | |||
| 60W (802.3bt): 7 | |||
| 90W (802.3bt): 5 | |||
| PSR920-54A-B | / | 770W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 12 | |||
| 90W (802.3bt): 8 | |||
| PSR1300-54D-B | / | 1150W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 19 | |||
| 90W (802.3bt): 12 | |||
| PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | / | 770W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 12 | |||
| 90W (802.3bt): 8 | |||
| PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | / | 1450W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 16 | |||
| PSR600-54A-B | PSR600-54A-B | 1020W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 17 | |||
| 90W (802.3bt): 11 | |||
| PSR600-54A-B | PSR920-54A-B | 1020W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 17 | |||
| 90W (802.3bt): 11 | |||
| PSR600-54A-B | PSR1300-54D-B | 1020W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 17 | |||
| 90W (802.3bt): 11 | |||
| PSR920-54A-B | PSR920-54A-B | 1600W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 17 | |||
| PSR920-54A-B | PSR1300-54D-B | 1600W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 17 | |||
| PSR920-54A-B | PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | 1260W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 21 | |||
| 90W (802.3bt): 14 | |||
| PSR920-54A-B | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 1600W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 17 | |||
| PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | 1600W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 17 | |||
| PSR1300-54D-B | PSR1300-54D-B | 2320W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 24 | |||
| PSR1300-54D-B | PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | 1480W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 16 | |||
| PSR1300-54D-B | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 2320W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 24 | |||
| PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 1600W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 17 | |||
| PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 2400W | 15.4W (802.3af): 24 |
| 30W (802.3at): 24 | |||
| 60W (802.3bt): 24 | |||
| 90W (802.3bt): 24 | |||